RW-100
Remote
Control RW-100 is now compatible with all models of Dorrough analog
and digital meters.
RW-100
Remote Control connects with up to four meters providing access
to all meter functions.
Button
legends on the top apply to analog meters and legends on the bottom
apply to digital meters.

Connections
to the meters are made through 8-pin mini DIN cables attached
to the Alarm/Remote connector on the rear of the meters. The RW-100
is powered by the meter(s) to which it is connected, and contains
a micro-controller to interrogate and serialize the switch status.
Alarm
indicators for up to four meters can be monitored on the RW-100
front panel. In addition, the meter alarm closure feature is also
duplicated on the rear panel.
Display
Functions
The
table lists the display functions.
|
Display
Function
|
Description
|
|
Ref
Mode
|
Expansion
mode enabling reference adjustment around "0"
to be within .1dB
|
|
Peak
Hold
|
Indefinite
Peak Hold
|
|
Peak
Auto
|
3
second Peak Hold
|
|
Clock
|
Overs
Reset
|
|
Full
Scale
|
Overs
Display
|
|
Phase
|
Displays
phase error as a correlator 0 to 180 on full scale
of meter
|
|
Sum/Diff
|
Sum
/ Diff display
|
|
Left/Right
|
Left/Right
display
|
|
Alarm
Functions
LED
alarms on the far left of the unit indicate phase errors, bit
stream corruption, overs, and loss of audio for each of 1 through
4 meters and are function selectable per the following table.
|
|
On
|
Off
|
|
Analog
Meters
(Dip Switch #4)
|
Phase
|
Loss
of Audio Full Scale
|
Digital
Meters
(Dip
Switch #4)
|
Phase
BSC*
|
Overs
BSC* Loss of Audio
|
|
*
Bit Stream Corruption
Model
RW-100 $250.00
The
rear panel of RW-100.
|